COOLING SPECIFICATIONS
CAUTION:
Do not use deionized water for cooling purposes. Deionized water causes
both corrosion and erosion of cooling manifolds.
Table 3‑3. Cooling specifications
Description
Specification
Coolant Requirements
Inlet water temperature
+5°C to +35°C (+41°F to +95°F)
Flow rate
7.6 lpm (2 gpm), minimum
Maximum inlet water pressure 6.9 bar (100 psi)
Pressure drop
See the following pressure drop figure
Contaminates
AE recommends the following specifications for the water
used to cool the Paramount MF 2 kW generator:
• pH between 7.0 and 9.0
• Total chlorine < 20 ppm
• Total nitrate < 10 ppm
• Total sulfate < 100 ppm
• Total dissolved solids < 250 ppm
• Total hardness expressed as calcium carbonate equivalent
less than 250 ppm
• Specific resistivity of 2500 Ω/cm or higher at 25°C
• Total dissolved solids (TDS) as estimated by the
following:
◦ TDS ≤ 640,000 ÷ specific resistivity (Ω/cm)