Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Returns 4 data bytes (one 32-bit value).
• Bytes 0 through 3 = Total energy output
in kWh
215
report real time
clock
Reports the system real time clock time and
date. The data received is encoded in Binary
Coded Decimal (BCD) format; for example: if
the value for seconds is 48, the data value
received will be 0x48. The real time clock
features automatic leap year compensation for
years up to 2100.
Returns 7 data bytes (8-bit values):
• Byte 0 = Seconds (valid values are 0 to
59)
• Byte 1 = Minutes (valid values are 0 to
59)
• Byte 2 = Hours (valid values are 0 to 23)
• Byte 3 = Day of the week (valid values
are 1 to 7)
◦ 1 = Sunday
◦ 2 = Monday
◦ 3 = Tuesday
◦ 4 = Wednesday
◦ 5 = Thursday
◦ 6 = Friday
◦ 7 = Saturday
• Byte 4 = Date (valid values are 1 to 31)
• Byte 5 = Month (valid values are 1 to 12)
• Byte 6 = Year (valid values are 00 to 99)
Set this value with command
70
.
0
7
219
report condensed
generator snapshot
data
Reports a selected collection of data identical
to the data reported by the individual
commands.
0
28
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑56
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...