Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
maximum external feedback value while the
output is on.
Valid values are from 10 V to 65535 V. If the
new maximum external feedback value is less
than the user external feedback limit, the unit
reduces the user external feedback limit to
equal to the new maximum external feedback
value.
Send 3 data bytes:
• Bytes 0 and 1 = Maximum external
feedback value in volts
• Byte 2 = Dummy byte for RFX II
compatibility (can contain any value)
14
set active control
mode
Sets the control mode. This mode cannot be
changed while the output is on.
Send 1 data byte (8-bit value):
• 2 = Host
• 4 =
User
port (analog)
• 8 = Diagnostic
Command
155
reports this value.
1
1
26
set pulsing
configuration
Set pulsing configuration. Set unit as master
or slave, turn pulse sync input on or off, set
memory mode, set explicit enable mode, and
enable or disable pulsing mode.
This command allows you to send
subcommands. Send a value in the first two
bytes that selects the parameter to set, and
then send subcommands to set parameter
values.
Byte 0-1 =
Subcommand
1
Set pulsing mode
2
Set pulse sync output
3
Reserved
4
Reserved
5
Set memory mode
6
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑23
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...