pulsing to the signal from the master. Configure the unit for master or slave operation
with host command
26
(subcommand 1).
Pulsing Parameters
Pulsing and its master/slave mode operate on a series of parameters.
Table 5‑8. Pulsing parameters
Parameter
Description
Command
Pulsing
master/slave
Sets a Paramount MF 2 kW generator to be a master unit or
a slave unit.
Set:
26
Report:
172
Pulse sync out Enables a signal (
PSYNC
) from a master unit that
synchronizes pulsing in slave units.
Set:
26
Report:
172
Pulsing
frequency
(Hz)
Sets the length of pulsing cycles; that is, the time from the
beginning of one RF on event to the beginning of the next
RF on event.
Set:
93
Report:
193
Pulsing duty
cycle (%)
Sets the percentage of each pulsing cycle for which output
is on.
Set:
96
Report:
196
Slave delay
Command not active
n/a
To Set Up Master/Slave Pulsing
To prepare for master/slave operation, you need a coaxial cable.
1. Make sure that RF output is off.
2. Connect one end of the coaxial cable to the
Pulse Out
connector (SMA) on the
unit that will be the master unit.
3. Connect the other end of the coaxial cable to the
Pulse In
connector (SMA) on
the unit that will be the slave unit. You can daisy-chain multiple units.
4. Using
AE Host
port command
26
, set the pulsing mode, master or slave mode,
and pulse sync output for each unit.
You can use
AE Host
port command
172
to report these values.
To Enable/Disable Pulsing and Set Pulsing Parameters
If your Paramount MF 2 kW generator has the pulsing option, you can enable or
disable pulsing output. You can make pulsing settings through any of the generator's
serial communication ports or Virtual Front Panel (VFP). If you are using VFP, see
the VFP help system for an explanation of how to enable or disable pulsing.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑28
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...