Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Returns 28 data bytes:
• Bytes 0 and 1 (16-bit value) = Forward
power in watts (see command
165
).
• Bytes 2 and 3 (16-bit value) = Reflected
power in watts (see command
166
).
• Bytes 4 and 5 (16-bit value) = Delivered
power in watts (see command
167
).
• Bytes 6 and 7 (16-bit value) = Power
setpoint in watts (see command
8
).
• Bytes 8 through 11 (32-bit value) = Real
impedance in hundredths of ohms (see
command
225
)
• Bytes 12 through 15 (32-bit value) =
Reactive impedance in hundredths of
ohms (see command
225
)
• Bytes 16 through 19 (32-bit value) =
Actual frequency in kHz (see command
147
)
• Bytes 20 through 23 (four 8-bit values) =
Process status (see command
162
)
• Byte 24 (8-bit value) = Regulation mode
(see command
154
)
• Byte 25 (8-bit value) = Control mode
(see command
155
)
• Bytes 26 and 27 (16-bit value) =
Coldplate temperature in degrees Celsius
(see command
228
)
225
report impedance
Reports the real and reactive impedance in
hundredths of ohms.
Returns 8 data bytes (two 32-bit values):
• Bytes 0 through 3 = Signed long integer
value of the real impedance
• Bytes 4 to 7 = Signed long integer value
of the reactive impedance
0
8
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑57
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...