Connecting AC Input Power
HARTING AC POWER CONNECTOR
The Paramount MF 2 kW generator provides a HARTING Han 70 A input power
connector that should be used with a four-conductor input cable.
B2
Ground
B1
A2
A1
Figure 5‑10. HARTING AC 70 A power input connector on back of unit
Table 5‑1. HARTING 70 A connector pin
descriptions
Pin
Description
A1
Phase
A2
Phase
B1
Phase
B2
Not connected
Gnd
Ground
The parts listed in the following table are those used on the Paramount MF 2 kW
generator HARTING AC connector. Do not order these parts. Contact HARTING to
find mating connector parts for the customer side of the AC connection.