Table 5‑4. Status LED indicators (Continued)
Status LED
Description
Over-temp
When lit, this yellow LED indicates that the unit's internal
temperature has exceeded its allowable level. The unit's output
power will be disabled until the temperature falls below the
internal temperature limit and the RF on command is toggled.
Fault
When lit, this yellow LED indicates that the unit has a fault
condition. The display will scroll through all error codes which
caused the fault.
While fault conditions are active, the unit's output power will be
disabled. Once the fault condition is cleared, send an RF off
command and then an RF on command, and output will be
enabled.
Generator LEDs
Table 5‑5. Generator LEDs
Generator LED
Display Value Description
Forward Power
Displays forward power in watts.
Reflected Power
Displays reflected power in watts.
Load Power
Displays load power in watts.
External Volts
Displays voltage on the SMA connector
Sense Voltage In
in
volts, multiplied by 200 (10 V is displayed as 2000 V).If nothing
is connected to the
Sense Voltage In
connector, the display
shows 2000 V.
Power Set Point
When the unit is in power control mode, displays power set point
in watts. When the unit is in voltage control mode, the display
will be dark when you scroll to this LED.
External Set Point
When the unit is in power control mode, the display will be dark
when you scroll to this LED.
When the unit is in voltage control mode, displays the voltage set
point in volts, multiplied by 200 (10 V is displayed as 2000 V).
Frequency
Displays output frequency in kHz.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑18
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...