Cmd
Data
ACK
Cmd
CSR
Header
Host computer
Unit
Chksum
Chksum
Header
ACK
Time
Figure 4‑17. Communications transaction example
AE HOST COMMANDS
The following sections describe the command status response (CSR) codes returned
by the Paramount MF 2 kW unit in response to a command, as well as the AE Host
commands for the Paramount MF 2 kW unit.
AE Host Command Status Response (CSR) Codes
When the Paramount MF 2 kW unit receives a command requesting a change in unit
operation (commands
1
through
127
), or when the Paramount MF 2 kW unit receives
any command that it rejects (commands
1
through
255
), it responds with a command
status response (CSR) code. The CSR is a single-byte number that indicates whether
the unit accepted or rejected the command and, in the case of rejection, the reason the
unit could not respond to the command.
Table 4‑9. AE Host command status response (CSR) codes
Code
Meaning
0
Command accepted
The following CSR codes are sent in response to a command that was not accepted
and provide an indication of why the command was not accepted
1
Control mode is incorrect
2
Output is on (change not allowed)
4
Command specifies a value that exceeds the limit for that parameter
5
User
port off signal is active.
7
One or more faults are active.
8
Set point ramping is active.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑19
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...