Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Send 1 data byte (8-bit value) to select the
software part number to be returned.
• Byte 0 = Software request
◦ 0 = Coldfire application firmware part
number
◦ 1 = Measurement board FPGA
firmware part number
◦ 3 = Bootloader firmware part number
◦ 13 = Display board application
firmware part number
◦ 14 = Display board FPGA firmware
part number
◦ 15 = Display board bootloader
firmware part number
Returns 7 data bytes:
• Bytes 0 through 6 = ASCII string
representing the software part number.
138
report tuning time-
out value
Reports the time in ms that the generator is
allowed to tune without finding a match
before it turns off RF output and activates a
fault. The maximum tuning time-out value is
60,000 ms. A value of 0 disables the tuning
time-out feature, causing the generator to tune
indefinitely.
Returns 4 data bytes:
• Bytes 0 through 4 = Time in ms
Set this value with command
38
.
0
4
139
report
communication
watchdog timer
Reports the communications watchdog timer
value in ms. A value of 0 ms indicates that the
watchdog timer is disabled. This parameter is
volatile and defaults to 0 each time you turn
the unit on. The maximum reported value is
65530 ms. The unit stores the watchdog timer
value internally in 10 ms increments and
truncates any fractional remainder. The unit
reports all values in multiples of 10 ms.
1
2
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑40
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...