Table 6‑1. Warning codes (Continued)
Warning Code
Problem Description
Suggested Action
303
UART 3 Buffer Overflow
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
320
UART 0 Receive Error
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
321
UART 1 Receive Error
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
322
UART 2 Receive Error
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
323
UART 3 Receive Error
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
FAULT CODES
Fault codes are displayed on the front panel and can also be accessed through serial
communication.
Table 6‑2. Fault codes
Fault Code
Problem Description
Suggested Action
19
EEPROM CRC Fault
Internal, unrecoverable fault
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
20
Hardware Initialization Fault
Internal, unrecoverable fault
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
21
RTOS Initialization Fault
Internal, unrecoverable fault
Cycle AC power to the unit.
If the fault persists, contact AE
Global Services.
22
EEPROM Initialization Fault
Internal, unrecoverable fault
Cycle AC power to the unit.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑9
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...