Table 4‑2. User port signal descriptions (Continued)
Description
Specification
Return wire should be connected to system ground.
Accuracy of voltage measurement: ± 0.6% or ± 20 mV.
The input impedance for all analog input signals is greater than
10 kΩ.
Analog outputs (AO)
Voltage range 0 V to 10 V
Return wire should be connected to system ground.
Accuracy of voltage measurement: ± 0.6% or ± 15 mV.
The load impedance for all analog output signals should be
greater than 1 kΩ.
Table 4‑3. 25-pin User port pin descriptions
Signal
Pin
Related
Pin
Name
Signal
Type
Description
1
14
SET POINT
STATUS
RETURN
Digital
output
See pin 14.
2
15
RFL PWR
MONITOR
Analog
output
This signal provides a linearly scaled
readback of reflected power.
• 0 V = 0 W
• 10 V = 1500 W
on page 4
‑
6 for the
wiring diagram.
3
16
FWD/LOAD
PWR MONITOR
Analog
output
This signal provides a linearly scaled
readback of forward power when the
generator is operated in forward power
regulation mode or the load power when
operated in load power regulation mode.
In voltage control mode, this signal
provides readback of forward power.
• 0 V = 0 W
• 10 V = Maximum rated output
power
on page 4
‑
7 for the
wiring diagram.
4
17
RF PWR ON
Digital
input
When logic high is applied to this pin,
RF output is enabled (if generator is in
user control mode). Logic low disables
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑3
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...