If you are not using the
User
port to control or monitor the unit, you can use a
“dummy” or “cheater” plug to satisfy these signals, thereby ignoring the
User
port.
To make a dummy plug, solder these jumpers on a mating connector.
Table 4‑1. Jumpers on a dummy plug to satisfy minimal signal requirements
Jumper Between Pins
Description
4 and 13
Connects
RF PWR ON
pin to
+15 V
pin
17 and 21
Satisfies
RF PWR ON
return to ground
10 and 23
Satisfies
INTERLOCK LOOP
signal
If desired, you can add an emergency off switch in series with the
RF PWR ON
signal
(pin 4) and/or tie your system interlocks in series with the generator
INTERLOCK
LOOP
signal (pins 10 and 23).
If the minimum requirements are met and then AC power is applied, RF output will
not automatically be activated. Choose a control mode, and then, to activate RF
output:
• If you are in host control mode, send an RF on command.
• If you are in user control mode, send an RF off signal and then an RF on signal.
25-Pin User Port Signal and Pin Descriptions
The following tables describe the 25-pin
User
port signals and pin descriptions.
Wiring diagrams are also provided.
Table 4‑2. User port signal descriptions
Description
Specification
Digital inputs (DI)
Optocouple-insulated
Logic high: 4 V to 25 V, typical input current 11 mA
Logic low: Less than 1 V
Digital outputs (DO)
Optocouplers open or close state
Open (high impedance): V maximum = 30 V (IC < 500 μA)
Close (low impedance): I maximum = 11 mA; Voltage drop is
less than:
• 1.2 V at 0.1 mA
• 3.2 V at 5 mA
• 5.6 V at 11 mA
Analog inputs (AI)
Voltage range 0 V to 10 V
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑2
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...