Satisfying Minimal Requirements for the 25-Pin User Port ..................... ....... 4-1
25-Pin User Port Signal and Pin Descriptions ......................................... ....... 4-2
Wiring Diagrams for the 25-Pin User Port ................................................ 4-6
AE Bus Transmission Parameters ................................................................ 4-11
DIP Switch and Switch Settings ............................................................. 4-12
Setting the Unit AE Bus Address ...................................................... ..... 4-13
AE Bus Command Number Byte ...................................................... ..... 4-15
AE Bus Optional Length Byte ........................................................... ..... 4-16
AE Bus Checksum Byte ......................................................................... 4-16
Creating an Ideal Communications Transaction ........................................... 4-17
T0: Host Transmits Message Packet ................................................ ..... 4-17
T1: Unit Verifies Host Transmission Packet ........................................... 4-17
T2: Unit Transmits Response to Host ............................................... ..... 4-18
T3: Host Acknowledges Unit Response ................................................. 4-18
AE Bus Communications Transaction Example ............................... ..... 4-18
AE Host Command Status Response (CSR) Codes ............................... ..... 4-19
Chapter 5. Installation, Setup, and Operation
Spacing and Mounting Requirements ..................................................... ....... 5-1
Connecting Output Power and Satisfying RF Connector Interlock ... ..... 5-12
Harting AC Power Connector ................................................................. 5-13
To Connect AC Input Power with the Harting Connector ....................... 5-14
Connecting I/O and Auxiliary Connectors ..................................................... 5-15
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
v
Table of Contents
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...