Table 6‑1. Warning codes (Continued)
Warning Code
Problem Description
Suggested Action
39
Out Of Setpoint Warning
Non-latching warning
•
Power Limit
LED on the
front panel will light
when this warning is
active.
• This warning can occur
anytime a nonfavorable
(high VSWR) load is
presented to the generator
output such that the unit
cannot produce the
requested delivered
power. The threshold for
this warning is ± 1% or
3 W, whichever is greater.
1. Ensure that you have set
the correct regulation
mode.
2. Check the RF output
cable connections and
integrity.
3. Ensure that your setpoint
is neither above nor
below power limits for
the generator.
If the warning persists, contact
AE Global Services.
50
DC Bus Low Warning
Non-latching warning
• AC line voltage is low
Verify that AC line voltage
meets specifications.
If the warning persists, contact
AE Global Services.
70
Auxiliary Temperature
Warning
Non-latching warning
• Auxiliary temperature is
higher than 60°C (140°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
inlet panel on the back of
the unit.
If the warning persists, contact
AE Global Services.
71
Auxiliary Cap Bank
Temperature Warning
Non-latching warning
• Cap bank temperature is
higher than 60°C (140°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
inlet panel on the back of
the unit.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑7
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...