Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
in volts. This command also returns the active
regulation mode.
Returns 3 data bytes (one 16-bit value, one 8-
bit value):
• Bytes 0 and 1 = setpoint value in watts or
volts
• Byte 2 = Output regulation mode
◦ 6 = Forward
◦ 7 = Delivered or load
◦ 8 = External (DC Bias)
Set the setpoint with command
8
and the
regulation mode with command
3
.
165
report forward
power
Reports the forward power in watts.
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = Forward power
0
2
166
report reflected
power
Reports the reflected power in watts.
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = Reflected power
Set this value with command
5
.
0
2
167
report delivered
power
Reports the delivered power in watts.
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = Delivered power
0
2
168
report DC bias
external feedback
Reports the external feedback value in volts as
measured at the DC bias input on the user
card.
Returns 2 data bytes.
• Bytes 0 and 1 = External feedback
Set this value with command
9
.
0
2
169
report user power
limit
Reports the user power limit in watts.
The user power limit is directly related to the
active regulation mode. For example, when in
load regulation mode, the user power limit
will limit delivered power.
0
2
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑50
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...