SETTING THE BAUD RATE
Use the DIP switch to set the serial AE Bus port baud rate.
Table 4‑5. DIP switch settings for variable baud rate, switches
6 and 7
Baud
Switch 6
Switch 7
9600
On
On
19200
On
Off
57600
Off
On
115200
Off
Off
DEFAULT DIP SWITCH SETTINGS
The default Host settings for the unit are AE Bus address 1, baud rate 19200, and
RS-232 communication mode.
Table 4‑6. Default dip switch settings
Switch
number
1
2
3
4
5
6
7
8
Default
position
on
on
on
on
off
on
off
on
SETTING THE UNIT AE BUS ADDRESS
Use the DIP switch to set the unit AE Bus address.
Table 4‑7. AE Bus address settings
Address
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
0
Do not assign this address to a unit; it is the AE Bus broadcast
address. All AE Bus units receive a message sent to this address by
the host, but will not reply. If you set the address to 0, the unit
automatically reassigns the address to 1
1
On
On
On
On
Off
2
On
On
On
Off
On
3
On
On
On
Off
Off
4
On
On
Off
On
On
5
On
On
Off
On
Off
6
On
On
Off
Off
On
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑13
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...