Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ 3 = Memory mode
Returns 4 data bytes.
• Bytes 0 and 1 = Parameter being
reported:
◦ 1 = DC bias mode
◦ 2 = SOA mode
◦ 3 = Memory mode
• Bytes 2 and 3 = Command data
(dependent on selection in previous two
bytes)
If you selected DC bias mode:
◦ 1 = Forward power limit
◦ 2 = Delivered power limit
If you selected SOA mode
◦ 0 = Disabled
◦ 1 = Enabled
If you selected memory mode:
◦ 0 = Volatile
◦ 1 = Nonvolatile
Set this value with command
118
; B0 = 50.
248
report fixed
frequency memory
mode
(subcommand 51)
Reports the setting of the fixed frequency
memory mode: either volatile or nonvolatile.
• When set to volatile, the fixed frequency
defaults to the center frequency on power
up.
• When set to nonvolatile, the fixed
frequency defaults to the factory default
fixed frequency setting or last setting if
changed from the factory default. See
product specification for the fixed
frequency factory default setting.
The factory default setting for this command
is configured for each product option. See the
product specification for the default setting.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑64
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...