Automatic Tuning Parameters
You can allow the tuning algorithm to sweep the entire range of generator
frequencies, or you can optimize the automatic tuning by setting tuning parameters.
For additional information on these parameters and how to use them, contact AE
Global Services..
describes frequency tuning parameters and shows the AE Host command
used to set or report each parameter value. See the AE Host for additional description
of the commands and parameter ranges.
Table 5‑7. Frequency tuning parameters
Parameter
Description
Command
Frequency tuning
mode
Toggles between automatic tuning and manual
frequency adjustment.
• Fixed: Turns automatic tuning off, allowing to set
or change generator frequency manually.
• Sweep: Turns automatic tuning on. The generator
will accept but not act on manual frequency
commands until placed back into fixed mode.
Set:
48
Report:
148
Start frequency
(kHz)
Sets the start frequency for automatic tuning. Must be
within the minimum and maximum specified
frequency.
Set:
46
Report:
146
Minimum
frequency (kHz)
Sets the low frequency limit for automatic tuning. Does
not affect the range of manual frequency setting.
Set:
44
Report:
144
Maximum
frequency (kHz)
Sets the high frequency limit for automatic tuning.
Does not affect the range of manual frequency setting.
Set:
45
Report:
145
Frequency step
maximum (Hz)
Sets the maximum single frequency step the generator
uses during automatic tuning. Large values are faster
but may cause overshoot. Smaller values are more
stable but may not keep up with a dynamic load.
Set:
118
,
subcommand
2
Report:
248
,
subcommand
2
Frequency step
minimum (Hz)
Sets the minimum single frequency step the generator
uses during automatic tuning. Large values are faster
but may cause overshoot. Smaller values are more
stable but may not keep up with a dynamic load.
Smaller values should be large enough to make the
resulting change in load reflection coefficient
significant when compared to system and measurement
fluctuations and noise.
Set:
118
,
subcommand
1
Report:
248
,
subcommand
1
Retuning threshold If parameter D increases beyond its tuned value plus
the retuning threshold value (D retuning
threshold), the generator starts the retuning process.
Set:
58
Report:
158
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑25
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...