Table 6‑2. Fault codes (Continued)
Fault Code
Problem Description
Suggested Action
32
Ambient Air Overtemperature
Fault
Latching fault
• Air temperature is higher
than 70°C (158°F)
1. Verify ambient
temperature at air inlet
on the side panel.
2. Verify that there is no
obstruction within
13 mm (0.5″) of the air
inlet panel.
If the fault persists, contact AE
Global Services.
36
RF Output Cable Interlock
Open Fault
Non-latching fault
• The RF output cable
interlock is open.
Verify that the RF output cable
is firmly attached.
If the fault persists, contact AE
Global Services.
37
User Port Interlock Open Fault
Non-latching fault
• Interlock at the
User
port
is not satisfied
Verify interlock.
If the fault persists, contact AE
Global Services.
40
Coldplate Temperature Rate
Fault
Latching fault
• Coolant flow rate and
temperature might be out
of specification
• Water might be flowing
in the wrong direction
• Water temperature is
rising too fast
• Verify that coolant
specifications for flow
rate and maximum
temperature are met.
• Verify that water is
flowing in the correct
direction.
If the fault persists, contact AE
Global Services.
47
AC Line Sag Fault
Latching fault
• AC line voltage is not
meeting specifications
Verify that AC line voltage
meets specifications.
If the fault persists, contact AE
Global Services.
48
DC Bus Low Fault
Latching fault
• AC line voltage is low
Verify that AC line voltage
meets specifications.
If the fault persists, contact AE
Global Services.
49
DC Bus High Fault
Non-latching fault
• AC line voltage is high
Verify that AC line voltage
meets specifications.
If the fault persists, contact AE
Global Services.
51
Bad Temperature Sensor Fault
Latching fault
Cycle AC power to the unit.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑11
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...