Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
60
set tune delay
Sets the time in ms that the tuning algorithm
waits before beginning to tune the generator
automatically. The unit stores this parameter
in nonvolatile memory. You cannot change
this setting while output is on. The maximum
tune delay value is 60,000 ms. The default
value is 50 ms.
Send 2 or 4 data bytes. If the value doesn't fit
into two bytes, it should be sent in four.
• Bytes 0 and 1 = Tune delay time in ms.
Command
160
reports this value.
2 or 4
1
61
set fixed frequency
Sets the generator output frequency when
operating in fixed frequency mode. You can
change the generator frequency while the
output is on when operating in the fixed
frequency mode. The fixed frequency value
must be within the unit frequency range.
For units that allow you to set the fixed
frequency memory mode (see command
118
;
B0 = 51), the fixed frequency parameter can
be set to either volatile or nonvolatile.
Some units allow you to retrieve minimum
and maximum fixed frequency settings with
command
161
.
Send 4 data bytes to set the value in kHz, or 5
data bytes to set the value in either kHz or Hz.
Send 4 data bytes (32-bit value):
• Frequency in kHz
Send 5 data bytes:
• Byte 0 = kHz or Hz
◦ 0 = Frequency is in kHz
◦ 1 = Frequency is in Hz
• Bytes 1 through 4 = Frequency value
Command
161
reports this value
4 or 5
1
70
set real time clock
Sets the system real time clock to the time/
date specified. The data transmitted must be
encoded in BCD (binary coded decimal)
7
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑30
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...