Table 6‑1. Warning codes (Continued)
Warning Code
Problem Description
Suggested Action
If the warning persists, contact
AE Global Services.
72
Auxiliary Coldplate
Temperature Warning
Non-latching warning
• Auxiliary coldplate
temperature is higher
than 60°C (140°F)
1. Verify ambient
temperature at air inlet
on the rear panel.
2. Verify that there is no
obstruction within
100 mm (4″) of the air
inlet panel on the back of
the unit.
If the warning persists, contact
AE Global Services.
73
Coldplate Temperature
Warning
Non-latching warning
Temperature is detected by a
thermistor.
• Coldplate temperature is
higher than 60°C (140°F)
• Coolant might be out of
specification
Verify that coolant
specifications for flow rate and
maximum temperature are
met.
If the warning persists, contact
AE Global Services.
74
SOA Protection Warning
Output power is being folded
back to prevent the unit from
exceeding the safe operating
area (SOA).
Check the process operation
parameters to ensure that they
are correct.
If the warning persists, contact
AE Global Services.
300
UART 0 Buffer Overflow
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
301
UART 1 Buffer Overflow
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
302
UART 2 Buffer Overflow
Warning
Non-latching warning
• Serial communication
hardware problem
Cycle AC power to the unit.
If the warning persists, contact
AE Global Services.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑8
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...