◦ 19200
◦ 57600
◦ 115200
• Paramount MF 2 kW unit addresses 1 to 31
• Odd parity
• One start bit, eight data bits, one stop bit
• Low-order bytes transmitted before high-order bytes (little endian)
The timeout period for the Paramount MF 2 kW unit is factory set at 0.75 seconds
(that is, no more than 0.75 seconds can elapse between bytes, or the unit will reset
and begin searching for a new message packet). Use command
40
to change this
value.
The host computer must finish one transaction with the Paramount MF 2 kW unit
before it initiates another transaction, either with the same unit or any other unit.
The Paramount MF 2 kW unit sends data through pin 2 (
TX RS-232
). This pin must
be connected to the receive pin (
RX RS-232
) on the host computer’s serial connector.
The receive pin is normally pin 2 for a standard, 9-pin serial port.
Host Port DIP Switches
DIP SWITCH AND SWITCH SETTINGS
Use the DIP switch to set the baud rate and the AE Bus address for your unit.
Baud rate
Unit address
Communication mode
Figure 4‑14. Slide DIP switch
The DIP switch contains eight individual switches. Setting a switch to the on position
means sliding the switch toward the numbers on the DIP, and setting a switch to the
off position means sliding it away from the numbers.
SWITCHES
The first five switches (1 to 5) specify the address of the unit, which a host computer
must include in the message packet it sends.
The next two switches (6 and 7) specify the AE Bus port baud rate.
Switch 8 (communication mode) is unused.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑12
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...