• Latching Faults: When these faults occur, regardless of whether RF is off or on
at the time that the fault occurs, they remain latched until the unit receives an
RF off command. If the cause of the fault has not cleared, the fault will not
clear.
• Non-Latching Faults: Faults that are self clearing when RF is off.
◦ Fault occurs when RF is off: A fault is non-latching only if the fault occurs
while RF is off. If the fault condition clears, the fault self clears. If the cause
of the fault has not cleared, the fault does not clear. The unit does not require
an RF off command before turning output on. As soon as the fault condition
clears, you can turn output on.
◦ Fault occurs when RF is on: If output was on when the fault occurred, output
turns off and the fault latches. The unit requires an RF off command before
turning output on.
• Non-Latching Warnings: Warnings self clear when the condition that caused the
warning clears. If a warning occurs while output is on, output remains on.
Warning and Fault Code Tables
The Paramount MF 2 kW generator provides both warning and fault codes for unit
troubleshooting.
• See
on page 6
‑
6 for warning code descriptions and suggested
actions.
• See
on page 6
‑
9 for fault code descriptions and suggested actions.
WARNING CODES
Warning codes can only be accessed through serial communication. Warning
39
also
causes the
Power Limit
LED on the front panel to light.
Table 6‑1. Warning codes
Warning Code
Problem Description
Suggested Action
32
Ambient Air Overtemperature
Warning
Non-latching warning
• Air temperature is higher
than 60°C (140°F)
1. Verify ambient
temperature at air inlet
on the side panel.
2. Verify that there is no
obstruction within
13 mm (0.5″) of the air
inlet panel.
If the warning persists, contact
AE Global Services.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Troubleshooting and Global Services
6‑6
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...