Communication Controls
25-PIN USER PORT
25-Pin User Port Connector
The
User
port uses a 25-pin, shielded, female, subminiature-D connector. Ground/
return lines are floating and need to be connected as close to the system as possible.
Pin 1
Pin 13
Pin 14
Pin 25
Figure 4‑1. User port connector, 25-pin
User Port Cabling Requirements
The cable used to connect the generator’s
User
port to the system controller must be
a shielded, 25-wire I/O cable. Twisted-pair wiring may be used but is not mandatory.
Signal losses should be minimized by keeping the cable length as short as possible.
The maximum recommended cable length between the generator and the controller is
10 meters (33′). To minimize interference from adjacent electrical equipment, the
EMI shield in the cable must be terminated to the metal shells of the cable’s
connectors. Additionally, the chassis of the generator must be tied to a local earth
ground through an adequately sized copper grounding strap.
Satisfying Minimal Requirements for the 25-Pin User Port
Regardless of whether you are controlling and monitoring the generator through the
User
port or through another port, two
User
port signals must be satisfied for the unit
to be operational:
RF PWR ON
(pin 4) and
INTERLOCK LOOP
(pins 10 and 23). In
other words, even if you are controlling the generator through the serial port
interface, the RF signal must be enabled on the
User
port, and the interlock satisfied.
☞
Important
If you are controlling your generator through a port other than the
User
port,
make sure that the control mode is set appropriately (to host mode to control
through the
Host
port, for example). The control mode can be set through an
AE Host command.
Paramount
®
MF 2 kW Generator
Chapter
4
57020114-00E
Communication Controls
4‑1
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...