Table 4‑9. AE Host command status response (CSR) codes (Continued)
Code
Meaning
9
Command’s data byte count is incorrect.
12
Feature is not available on this unit.
17
Minimum off time is active.
28
Set point exceeds user limit.
30
EEPROM read/write error.
41
One or more warnings are active.
42
DHCP is active.
50
Frequency is out of range.
51
Duty cycle is out of range.
52
Minimum on or off time is violated.
61
Real time clock was busy.
63
Flash mode is active.
99
Command not accepted (there is no such command).
AE Host Command Set
• Commands
1
through
127
request a change to the Paramount MF 2 kW unit,
such as changing a setting in the unit. The unit responds to these commands by
sending a command status response (CSR). This single-byte response indicates
whether the unit has accepted or rejected the command and, in the case of
rejection, the reason the unit could not respond to the command.
• Commands
128
through
255
request information from the unit, such as unit
settings. The unit responds to these commands by sending the data requested if
the command was successful, and a CSR if the command was not successful.
Unless otherwise specified for individual commands, AE Bus protocol is little
endian, which means that all values greater than 1 byte are sent least significant byte
first.
Table 4‑10. AE Host commands
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
1
RF Off
Turns RF output off. Accepted regardless of
control mode. This command explicitly clears
all latched faults, but it does not clear any
faults that are currently active.
Command
162
reports this value.
0
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑20
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...