Table 3‑2. Electrical specifications (Continued)
Description
Specification
Measured power accuracy
into 4.79:1 VSWR circle
Power accuracy:
• ± 2 W of setpoint for 5 W to 50 W, over entire frequency range
• ± 3.5% of setpoint or ± 2 W for 50 W to 2000 W, whichever is
greater, over entire frequency range
Repeatability (same
generator) over the full
frequency and power
range into 50 Ω non-
reactive load
Same generator repeatability:
• ± 1 W of setpoint for 5 W to 50 W
• ± 1% of setpoint or ± 1.5 W, whichever is greater, when
operating at 400 kHz, into a 50 Ω, nonreactive load for 50 W
to 2000 W
• ± 1.5% of setpoint or ± 2 W, whichever is greater, over entire
frequency range when operated into a 50 Ω, nonreactive load,
for 50 W to 2000 W
Repeatability generator-
to-generator over the full
frequency and power
range into 50 Ω non-
reactive load
< 2.0% or 4 W, whichever is greater, from 50 W to 2000 W into a
50 Ω, non-reactive load
Load mismatch stability
over full frequency and
power range
The generator will operate continuously into any load impedance
without failure.
Short term output power
drift operating into a 50 Ω
load
< 1.0% during one continuous hour of operation beginning with a
setpoint of 0 W at 400 kHz and giving the generator a 2000 W
setpoint operating into a 50 Ω load.
RF on/off response time
Analog
User
interface:
• RF rise time: < 20 ms from leading edge of
RF ENABLE
signal
to 81% of setpoint (90% of the output voltage) provided a
single command received by the generator. No overshoot.
• RF fall time: < 6 ms from falling edge of
RF ENABLE
signal
to < 5 W provided a single command received by the
generator.
RF on/off response time
Serial
Host
interface:
• RF rise time: < 20 ms upon receipt of AE Bus command to
81% of setpoint provided a single command received by the
generator. No overshoot.
• RF fall time: < 6 ms upon receipt of AE Bus command to <
5 W provided a single command received by the generator.
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Specifications
3‑5
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...