Table 4‑7. AE Bus address settings (Continued)
Address
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
7
On
On
Off
Off
Off
8
On
Off
On
On
On
9
On
Off
On
On
Off
10
On
Off
On
Off
On
11
On
Off
On
Off
Off
12
On
Off
Off
On
On
13
On
Off
Off
On
Off
14
On
Off
Off
Off
On
15
On
Off
Off
Off
Off
16
Off
On
On
On
On
17
Off
On
On
On
Off
18
Off
On
On
Off
On
19
Off
On
On
Off
Off
20
Off
On
Off
On
On
21
Off
On
Off
On
Off
22
Off
On
Off
Off
On
23
Off
On
Off
Off
Off
24
Off
Off
On
On
On
25
Off
Off
On
On
Off
26
Off
Off
On
Off
On
27
Off
Off
On
Off
Off
28
Off
Off
Off
On
On
29
Off
Off
Off
On
Off
30
Off
Off
Off
Off
On
31
Off
Off
Off
Off
Off
AE Bus Protocol
The AE Bus protocol uses pure binary data (nothing is coded in ASCII) and is
designed to facilitate direct communications between a host computer and the
Paramount MF 2 kW unit. The AE Bus message packet combines a set quantity of
bits and bytes in such a way that groups of information can be sent over
communications lines at one time. Five types of information (fields) make up a
communications message packet.
• Header (address and the length of data field)
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑14
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...