Table 5‑6. Recommended command sequence and timing
Sequence description
Command sequence
1
Issue commands in this order from the indicated interface:
1. Set to voltage control (DC bias) mode at the
User
port.
2. Wait 20 ms.
3. Turn RF ON at the
User
port.
4. Wait 10 ms.
5. Set voltage set point at the
User
port.
To set the unit to voltage
control (DC bias) mode with a
set point and turn RF on when:
• RF is off
• Unit is set to power
regulation mode
• Set point is zero
2
Issue commands in this order from the indicated interface:
1. Set to voltage control (DC bias) mode at the
User
port.
2. Wait 10 ms.
3. Set voltage set point at the
User
port.
4. Wait 20 ms.
5. Turn RF ON at the
User
port.
To set the unit to voltage
control mode with a set point
and turn RF on when:
• RF is off
• Unit is set to power
regulation mode
• Set point is zero
3
Issue commands in this order from the indicated interface:
1. Set to power regulation mode at the
User
port.
2. Wait 10 ms.
3. Set to load power regulation at the
User
port.
4. Wait 10 ms.
5. Turn RF ON at the
User
port.
6. Wait 20 ms.
7. Set power set point at the
User
port.
To set the unit to load power
regulation with a set point and
turn RF on when:
• RF is off
• Unit is set to voltage
control (DC bias) mode
• Set point is zero
• Forward power regulation
setting is active
4
Issue commands in this order from the indicated interface:
1. Set to power regulation mode at the
User
port.
2. Wait 10 ms.
3. Set to load power regulation at the
User
port.
4. Wait 10 ms.
5. Set power set point at the
User
port.
6. Wait 20 ms.
To set the unit to load power
regulation mode and with a set
point and turn RF on when:
• RF is off
• Unit is set to voltage
control (DC bias) mode
• Set point is zero
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑21
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...