Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
The following table shows the factory set/
default values for pulsing parameters.
Parameter
Factory Set/
Default Value
Pulsing mode
Master mode
Enable pulse sync
output
Pulse sync output
enabled
Memory mode
RAM
26
set pulsing mode
(subcommand 1)
Sets the unit pulsing mode to master or slave.
You can not use this command while RF
output is on.
Send 6 data bytes.
• Bytes 0 and 1 = 1 (set pulsing mode)
• Bytes 2 and 3 = Pulsing mode
◦ 1 = Master mode
◦ 2 = Slave mode
• Bytes 4 and 5 = Reserved
Command
172
B0 = 1 reports these values.
6
1
26
enable pulse sync
output
(subcommand 2)
Enables or disables pulse sync output.
Send 6 data bytes.
• Bytes 0 and 1 = 2 (enable/disable pulse
sync output)
• Bytes 2 and 3 = Pulse sync output on or
off
◦ 0= Pulse sync output off
◦ 1= Pulse sync output on
• Bytes 4 and 5 = Reserved
Command
172
B0 = 2 reports these values.
6
1
26
set memory mode
(subcommand 5)
Sets the unit memory mode to RAM or
NVRAM. The unit saves parameters to the
currently active memory as specified by this
value. Future parameter changes will also be
saved to the current active memory.
6
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑24
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...