Table 5‑6. Recommended command sequence and timing (Continued)
Sequence description
Command sequence
• Forward power regulation
setting is active
7. Turn RF ON at the
User
port.
5
Issue commands in this order from the indicated interface:
1. Send an RF OFF command at the
User
port.
2. Wait 10 ms.
3. Set to power regulation mode at the
User
port.
4. Wait 10 ms.
5. Set to load power regulation at the
User
port.
6. Wait 10 ms.
7. Set power set point at the
User
port.
To set the unit to load power
regulation mode with a set
point and leave RF off when:
• RF is on
• Unit is set to voltage
control (DC bias) mode
• Forward power regulation
setting is active
6
Issue commands in this order from the indicated interface:
1. Send an RF OFF command at the
User
port.
2. Wait 10 ms.
3. Set to voltage control (DC bias) mode at the
User
port.
4. Wait 10 ms.
5. Set voltage set point at the
User
port.
To set the unit to voltage
control (DC bias) mode with a
set point and leave RF off
when:
• RF is on
7
Issue commands in this order from the indicated interface:
1. Set to voltage control (DC bias) mode at the
User
port.
2. Wait 5 ms.
3. Set pulse frequency at the
Host
port.
4. Wait 10 ms.
5. Set pulse duty cycle at the
Host
port.
6. Wait 5 ms.
7. Set voltage set point at the
User
port.
8. Wait 20 ms.
9. Turn RF ON at the
User
port.
To set the unit to voltage
control (DC bias) mode with a
set point, pulsing frequency,
pulsing duty cycle, and turn RF
on when:
• RF is off
• Unit is in power
regulation mode
8
Issue commands in this order from the indicated interface:
1. Set to power regulation mode at the
User
port.
2. Wait 10 ms.
3. Set to load power regulation at the
User
port.
To set the unit to load power
regulation mode with pulse
frequency, pulse duty cycle, a
set point, and turn RF on when:
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Installation, Setup, and Operation
5‑22
Содержание Paramount MF 2 kW
Страница 2: ...Paramount MF 2 kW Generator User Manual January 2018 57020114 00E...
Страница 31: ...Figure 3 2 Pressure drop Advanced Energy Paramount MF 2 kW Generator 57020114 00E Specifications 3 12...
Страница 103: ...3710 Figure 5 5 Left side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 6...
Страница 105: ...3712 Figure 5 7 Top side Advanced Energy Paramount MF 2 kW Generator 57020114 00E Installation Setup and Operation 5 8...