1.3 C: Tuning
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
83
Pa
ra
m
et
er D
et
ai
ls
1
Figure 1.27
Figure 1.27 Slip Compensation Limit
■
C3-04: Slip Compensation Selection during Regeneration
When the slip compensation during regeneration function has been activated and
regeneration capacity increases momentarily, it might be necessary to use a braking option
(braking resistor, braking resistor unit, or braking unit.)
Even if enabled, this function does not operate when the output frequency is too low.
Setting 0: Disabled
Slip compensation is not provided. Depending on the load and operation mode (motoring or
regenerative) the actual motor speed will be lower or higher than the frequency reference.
Setting 1: Enabled
Slip compensation is enabled during regenerative operation. It will not be active at output
frequencies below 6 Hz.
■
C3-05: Output Voltage Limit Operation Selection
Determines if the motor flux reference is automatically reduced when output voltage reaches
the saturation range.
No.
Parameter Name
Setting Range
Default
C3-04
Slip Compensation Selection during Regeneration
0 or 1
0
No.
Parameter Name
Setting Range
Default
C3-05
Output Voltage Limit Operation Selection
0 or 1
0
E1-04
E1-06 × C3-03
C3-03
E1-04
Maximum
Frequency
E1-06
Base
Frequency
Output frequency