2.9 MEMOBUS/Modbus Data Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
279
ME
MOBUS/Mo
dbus
C
ommuni
cat
io
ns
2
002CH
Drive Status 2
bit 0
During Run
bit 1
Zero Speed
bit 2
Speed Agree
bit 3
User Speed Agree
bit 4
Frequency Detection 1
bit 5
Frequency Detection 2
bit 6
Drive Ready
bit 7
During Undervoltage
bit 8
During Baseblock
bit 9
Frequency Reference from Operator Keypad
bit A
Run Command from Operator Keypad
bit B
Over/Undertorque 1, 2
bit C
Frequency Reference Loss
bit D
During Fault Restart
bit E
Fault
bit F
Communication Timeout
002DH
Output Terminal Status
bit 0
Multi-Function Contact Output (terminal MA/MB-MC)
bit 1
Multi-Function Photocoupler Output 1 (terminal P1 - PC)
bit 2
Multi-Function Photocoupler Output 2 (terminal P2 - PC)
bit 3 - 6
Reserved
bit 7
Fault Contact (terminal MA/MB-MC)
bit 8 to bit F
Reserved
002EH Reserved
002FH
Frequency Reference Bias (from Up/ Down 2 Function), 0.1% units
0030H
Reserved
0031H
DC Bus Voltage, 1 Vdc units
0032H
Torque Monitor, 1% units
0033H
Reserved
0034H
Product Code 1 [ASCII], Product Type (V0 for V1000)
0035H
Product Code 2 [ASCII], Region Code
0036H to 0037H
Reserved
0038H
PID Feedback, 0.1% units, unsigned, 100% / max. output frequency
0039H
PID Input, 0.1% units, signed, 100% / max. output frequency
003AH
PID Output, 0.1% units, signed, 100% / max. output frequency
003B to 003CH
Reserved
Register No.
Contents