1.3 C: Tuning
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
93
Pa
ra
m
et
er D
et
ai
ls
1
Table 1.28 Drives with Heavy Duty Default Carrier Frequency of 8 kHz
200 V Single Phase Units
200 V Three Phase Units
400 V Three Phase Units
Model
VZA~
Rated Current [A]
Model
VZA~
Rated Current [A]
Model
VZA~
Rated Current [A]
2 kHz
8 kHz
15 kHz
2 kHz
8 kHz
15 kHz
2 kHz
8 kHz
15 kHz
B1P5
9.6
8.0
6.4
21P5
9.6
8.0
6.4
40P2
1.2
1.2
0.7
B2P2
12.0
11.0
8.8
22P2
12.0
11.0
8.8
40P4
2.1
1.8
1.1
B4P0
17.5
17.5
14.0
24P0
19.6
17.5
14.0
40P7
4.1
3.4
2.0
25P5
30.0
25.0
20.0
41P5
5.4
4.8
2.9
27P5
40.0
33.0
26.4
42P2
6.9
5.5
3.3
2011
56.0
47.0
37.6
43P0
8.8
7.2
4.3
2015
69.0
60.0
48.0
44P0
11.1
9.2
5.5
45P5
17.5
14.8
8.9
47P5
23.0
18.0
10.8
4011
31.0
24.0
14.4
4015
38.0
31.0
18.6