A.2 Parameter Table
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
319
Para
me
te
r Lis
t
A
E3-04
Motor 2 Max
Output
Frequency
These parameters set the V/f pattern for motor
2.
To set linear V/f characteristics, set the same
values for E3-07 and E3-09. In this case, the
setting for E3-08 will be disregarded. Ensure
that the four frequencies are set according to
these rules or OPE10 fault will occur:
E3-04
≥
E3-06 > E3-07 > E3-09
40.0 to
400.0
50 Hz
A A
−
31A
E3-05
Motor 2 Max
Voltage
0.0 to
255.0
200.0
V
A A
−
31B
E3-06
Motor 2 Base
Frequency
0.0 to E3-
04
50 Hz
A A
−
31C
E3-07
Motor 2 Mid
Output Freq.
0.0 to E3-
04
2.5 Hz
A A
−
31D
E3-08
Motor 2 Mid
Output Freq.
Voltage
0.0 to
255.0
16.0 V
A A
−
31E
E3-09
Motor 2 Min.
Output Freq.
0.0 to E3-
04
1.3 Hz
A A
−
31F
E3-10
Motor 2 Min.
Output Freq.
Voltage
0.0 to
255.0
12.0 V
A A
−
320
E3-11
Motor 2 Mid
Output
Frequency 2
0.0 to E3-
04
0.0 Hz A A
−
345
E3-12
Motor 2 Mid
Output
Frequency
Voltage 2
0.0 to
255.0
0.0 Vac A A
−
346
E3-13
Motor 2 Base
Voltage
0.0 to
255.0
0.0 Vac A
S
−
347
E4: Motor 2 Parameters
Use E4 parameters to control a second motor operating on the same drive.
E4-01
Motor 2 Rated
Current
Sets the motor 2 nameplate full load current in
amperes (A). This value is automatically set
during Auto-Tuning.
10 to
200% of
drive
rated
current
A A
−
321
E4-02
Motor 2 Rated
Slip
Sets the motor 2 rated slip in Hz.
Automatically set during Auto-Tuning.
0.00 to
20.00
A A
−
322
E4-03
Motor 2 Rated
No-Load
Current
Sets the magnetizing current of motor 2 in
Ampere. Automatically set during Rotational
Auto-Tuning.
0 to less
than
E4-01
A A
−
323
No.
Name
Description
Range
Def.
Control
Mode
Addr.
Hex
Pg.
V/f
OL
V
PM
VACrms Out (V)
Frequency (Hz)
E3-09 E3-07 E3-06 E3-11 E3-04
E3-05
E3-12
E3-13
E3-08
E3-10
Summary of Contents for OYMC V1000
Page 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Page 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Page 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...