1.10 o: Operator Related Settings
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
235
Pa
ra
m
et
er D
et
ai
ls
1
• U1-02: output frequency
• U1-05: motor speed
• U1-16: output frequency after softstarter (accel/decel ramp generator)
• d1-01 to d1-17: frequency references
Setting 0: Hz
The frequency reference and monitors are displayed in Hz with a resolution of 0.01 Hz.
Setting 1: %
The frequency reference and monitors are displayed as a percentage with a resolution of
0.01%. 100% is equal to the maximum output frequency.
Setting 2: r/min
The frequency reference and monitors are displayed in r/min with a resolution of 1 r/min.
For correct display values, the number of motor poles must be entered into parameters E2-
04, E4-04, or E5-04, depending on which motor setting is used.
Setting 3: User-Set Display Units
The frequency reference and monitors are displayed with the maximum value and resolution
defined by parameters o1-10 and o1-11. The default display unit when o1-03 = 3 is
100.00%.
■
o1-10: User-Set Display Units Maximum Value
Determines the display value that is equal to the maximum output frequency. The decimal
number is defined by parameter o1-11.
Note:
This setting changes automatically when o1-03 is changed. o1-10 can only be adjusted when o1-
03 is set to 3.
■
o1-11: User-set Display Units Decimal Display
Determines the number of digits for user-set display if o1-03 is set to 3. The setting value is
equal to the number of decimal places. The maximum display value is defined by o1-10.
Note:
This setting changes automatically when o1-03 is changed. o1-11 can only be adjusted when o1-
03 is set to 3.
No.
Name
Setting Range
Default
o1-03
Digital Operator Display Selection
0 to 3
0
No.
Name
Setting Range
Default
o1-10
User-Set Display Units Maximal Value
1 to 60000
Determined by
o1-03