1.6 F: Option Settings
132
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
Setting 0: Disabled, Auto Reset not Possible
Setting 1: Enabled, Auto Reset Possible
■
F6-30: PROFIBUS Node Address
Sets the node address of a PROFIBUS-DP option card if installed.
■
F6-31: PROFIBUS Clear Mode Selection
Determines the operation when a “Clear Mode” command is received.
Setting 0: Reset
Resets the drive operation (frequency reference, inputs, outputs etc.).
Setting 1: Maintain the Previous State
Keeps the drive status the same as what it was before the Clear Mode command was
received.
■
F6-32: PROFIBUS Data Format Selection
Selects the data format used for Profibus communication.
Setting 0: PPO Type Data Format
Setting 1: Conventional Data Format
■
F6-35: CANopen Node ID Selection
Selects the node ID of a CANopen option board if installed.
No.
Parameter Name
Setting Range
Default
F6-30
PROFIBUS Node Address
0 to 125
0
No.
Parameter Name
Setting Range
Default
F6-31
PROFIBUS Clear Mode Selection
0 or 1
0
No.
Parameter Name
Setting Range
Default
F6-32
PROFIBUS Data Format Selection
0 or 1
0
No.
Parameter Name
Setting Range
Default
F6-35
CANopen Node ID Selection
0 to 127
99