A.5 Defaults Determined by Drive Capacity (o2-04) and Normal/Heavy
382
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
No.
Description
Unit
Default Settings
−
Model VZA
−
27P5
2011
2015
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
HD
ND
o2-04
Drive Model Selection
Hex
6B
6D
6E
E2-11
(E4-11,
T1-02)
Motor rated power
kW
7.5
11.0
11.0
15.0
15.0
18.5
b3-06
Speed Search current 1
−
0.5
0.5
0.5
0.5
0.5
0.5
b8-04
Energy saving coefficient
−
72.69
70.44
70.44
63.13
63.13
57.87
C6-02
Carrier frequency
−
3
7
3
7
3
7
E2-01
(E4-01,
T1-04)
Motor rated current
A
26.6
39.7
39.7
53
53
65.8
E2-02
(E4-02)
Motor rated slip
Hz
1.3
1.7
1.7
1.6
1.6
1.67
E2-03
(E4-03)
Motor no-load current
A
8.0
11.2
11.2
15.2
15.2
15.7
E2-05
(E4-05)
Motor line-to-line
resistance
Ω
0.288
0.230
0.230
0.138
0.138
0.101
E2-06
(E4-06)
Motor leakage inductance
%
15.5
19.5
19.5
17.2
17.2
15.7
E2-10
(E4-10)
Motor Iron Loss
W
262
245
245
272
272
505
E5-01
Motor Code
hex
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
L2-02
Momentary power loss
ride-through time
s
1.0
1.0
2.0
2.0
2.0
2.0
L2-03
Momentary power loss
Baseblock time
s
0.8
0.9
0.9
1.0
1.0
1.0
L2-04
Momentary power loss
voltage recovery time
s
0.3
0.3
0.3
0.3
0.6
0.6
L2-05
UV detection voltage
V dc
190
190
190
190
190
190
L3-24
Motor acceleration time
s
0.175
0.265
0.265
0.244
0.244
0.317
L8-02
Overheat alarm level
°
C
121
121
120
120
120
120
L8-09
Ground fault selection
−
1
1
1
1
1
1
L8-35
Installation Method Sel.
−
2
2
2
2
2
2
L8-38
Carrier frequency
reduction selection
−
2
2
2
2
2
2
n1-03
Hunting Prevention Time
Constant
ms
10
10
10
10
10
10
Summary of Contents for OYMC V1000
Page 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Page 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Page 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...