1.10 o: Operator Related Settings
236
YASKAWA ELECTRIC
SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
◆
o2: Operator Key Selections
These parameters determine the functions assigned to the operator keys.
■
o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled
or not for switching between LOCAL and REMOTE.
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible
during stop only. When LOCAL is selected, the LED indicator on the LO/RE key will light
up.
NOTICE: When parameter b1-07 is set to 1 and the drive is switched from LOCAL to REMOTE while the
Run command at the REMOTE source is active, operation will start immediately. Refer to
REMOTE Run Selection on page 45
for details and warnings.
■
o2-02: STOP Key Function Selection
Selects if the STOP key on the digital operator can be used to stop the operation when the
drive is controlled from a remote source (i.e., not from digital operator)
Setting 0: Disabled
The STOP key has no function when the drive is controlled by a source other than the digital
operator. The drive can only be stopped from the Run command source that has been
selected.
No.
Name
Setting Range
Default
o1-11
User-Set Display Units Decimal Display
0 to 3
Determined by
o1-03
No.
Name
Setting Range
Default
o2-01
LO/RE Key Function Selection
0 or 1
1
No.
Name
Setting Range
Default
o2-02
STOP Key Function Selection
0 or 1
1
Summary of Contents for OYMC V1000
Page 2: ...2 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual...
Page 8: ...8 YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual INDEX 393...
Page 407: ...YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive V1000 PRELIM Programming Manual 407...