A.6 Parameters that Change with the Motor Code Selection
YASKAWA ELECTRIC SIEP C710606 10A YASKAWA AC Drive - V1000 PRELIM. Programming Manual
391
Para
me
te
r Lis
t
A
Par.
Description
Unit
Default Settings
E5-01
Motor Code
−
123A
123B
123D
123E
Voltage class
−
400 Vac
400 Vac
400 Vac
400 Vac
Rated power
−
5.5 kW
7.5 kW
11 kW
15 kW
Rated speed
r/min
1750
1750
1750
1750
E5-02
Motor rated power
kW
5.5
7.5
11.0
15
E5-03
Motor rated current
A
9.90
13.10
19.9
26.4
E5-04
Motor pole number
–
6
6
6
6
E5-05
Motor winding resistance
W
0.982
0.786
0.368
0.263
E5-06
d-axis inductance
mH
22.7
16.49
13.38
10.51
E5-07
q-axis inductance
mH
26.80
23.46
16.99
12.77
E5-09
Induction voltage constant 1
mVs/rad
498.0
541.7
508.7
531.9
E5-24
Induction voltage constant 2 mV/(r/min)
0.0
0.0
0.0
0.0
E1-04
Maximum output frequency
Hz
87.5
87.5
87.5
87.5
E1-05
Maximum output voltage
V
380.0
380.0
380.0
380.0
E1-06
Base voltage
Hz
87.5
87.5
87.5
87.5
E1-09
Minimum output frequency
Hz
4.4
4.4
4.4
4.4
L3-24
Motor acceleration time
s
0.083
0.077
0.084
0.102
n8-49
Pull-in current
%
–10.2
–17.4
–15.8
–12.6