Repairs and Adjustments
Initial Issue
REP 6.0.11 Output Tray Full Sensor
Parts List on PL 6.0
Removal
The Output Tray Full Sensor consists of two circuit boards mounted on either side of the Output
Tray. Replace both boards when servicing this sensor.
1.
Remove the Scanner Assembly with attached DADF (REP 1.0.11).
2.
Remove the Output Tray (REP 1.0.6).
3.
Remove the Left Side Cover (REP 1.0.7).
4.
Remove the Right Side Cover (REP 1.0.21).
5.
Remove the Exit Elevator Motor (REP 4.0.9).
6.
Disconnect the Output Tray Full Sensor connectors (CN801 and CN802).
7.
Remove 2 (plastic, T-20) screws that secure the left and right boards to the chassis.
Figure 1 Removing the Output Tray Full Sensor
Summary of Contents for PHASER 8560MFP
Page 1: ...701P01133 October 2006 Phaser 8560MFP Multifunction Product Service Documentation...
Page 4: ...10 2006 iv Phaser 8510 8560MFP Multifunction Product Initial Issue Introduction...
Page 22: ...10 2006 1 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Service Call Procedures...
Page 28: ...10 2006 2 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Error Messages and Codes...
Page 84: ...10 2006 3 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Image Quality...
Page 116: ...10 2006 4 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Repairs and Adjustments...
Page 194: ...10 2006 5 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Parts List...
Page 204: ...10 2006 6 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Diagnostics...
Page 256: ...10 2006 7 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Wiring Data...
Page 274: ...10 2006 8 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Theory of Operation...