10/2006
4-27
Phaser 8510/8560MFP Multifunction Product
REP 2.0.8
Repairs and Adjustments
Initial Issue
Figure 4 X-Axis Bias Spring Hook
11. Disconnect the Air Hose from the Purge Pump.
12. Remove 1 (plastic, T-20) screw that secures each Printhead Restraint, and then shift the
restraint inwards toward the Printhead while lifting toward the rear of the printer.
Figure 5 Removing the Printhead Restraint Screws
NOTE: Use a flat-bladed screwdriver to rotate the X-Axis Motor to adjust the Printhead
position as needed to remove the Printhead Restraints.
Figure 6 Removing the Printhead Restraints