Repairs and Adjustments
REP 5.0.26 FDI Board
Parts List on PL 5.0
Removal
1.
Remove the Scanner Assembly with attached DADF (REP 1.0.11).
2.
Remove the Output Tray (REP 1.0.6).
3.
Remove the Right Side Cover (REP 1.0.21).
4.
Disconnect the harnesses from the FDI board.
5.
Remove the 3 (2 metal, T-20, 1 plastic T-20) screws that secure the board to the chassis.
Figure 1 Removing the FDI Board
REP 6.0.1 Scanner Detect Sensor
Parts List on PL 6.0
Removal
1.
Remove the Scanner Assembly with attached DADF (REP 1.0.11).
2.
Remove the Output Tray (REP 1.0.6).
3.
Remove the Left Side Cover (REP 1.0.7).
4.
Flex the retaining hook to the right to remove the sensor from the chassis.
5.
Disconnect the sensor (CN851) from the harness.
Figure 1 Removing the Scanner Detect Sensor
Summary of Contents for PHASER 8560MFP
Page 1: ...701P01133 October 2006 Phaser 8560MFP Multifunction Product Service Documentation...
Page 4: ...10 2006 iv Phaser 8510 8560MFP Multifunction Product Initial Issue Introduction...
Page 22: ...10 2006 1 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Service Call Procedures...
Page 28: ...10 2006 2 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Error Messages and Codes...
Page 84: ...10 2006 3 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Image Quality...
Page 116: ...10 2006 4 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Repairs and Adjustments...
Page 194: ...10 2006 5 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Parts List...
Page 204: ...10 2006 6 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Diagnostics...
Page 256: ...10 2006 7 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Wiring Data...
Page 274: ...10 2006 8 2 Phaser 8510 8560MFP Multifunction Product Initial Issue Theory of Operation...