PROCEDURE
1
Attach the
(001,
) to the holder (002).
2
Turn the proximity sensor (001) fully down until the tip of the proximity sensor touches
the bottom of the holder (002).
NOTE:
During installation/commissioning the clearance between the flywheel tooth
(001) and the holder (002) is set to 4
0
-0.2
mm.
3
Loosen the proximity sensor (001) a half turn to get a clearance of 4
0
-0.2
mm between the
flywheel tooth (004) and the bottom face of the proximity sensor.
4
Carefully tighten the locknut (003) with your fingers.
5
Connect the electrical connection to the proximity sensor (001). Refer to the mark made
before to identify the correct cable.
X82-B
AA00-9223-01AAA-720A-A
Maintenance Manual
Crank angle sensor unit (supply unit) - proximity sensor - install
Winterthur Gas & Diesel Ltd.
- 765 -