![WinGD X82-B Maintenance Manual Download Page 50](http://html1.mh-extra.com/html/wingd/x82-b/x82-b_maintenance-manual_986581050.webp)
•
Rules for electric welding
Do electric welding near the engine only if the engine is stopped.
Set to OFF the electronic system and wait a minimum of one minute.
Disconnect electronic modules or sensors in a radius of two meters from the welding
place.
Make sure that there are no explosive fluids or gases in the work area.
Apply protection to electronic parts to prevent damage from sparks and heat.
Place the connection to earth as near as possible to the welding object.
Make sure that the welding cable has no loops and is not parallel to cables of electronic
units.
X82-B
AA00-0000-00AAA-012A-A
Maintenance Manual
Safety precautions and safety rules
Winterthur Gas & Diesel Ltd.
- 50 -