PROCEDURE
1
Prepare the overpressure safety valve.
1.1
Attach the overpressure safety valve (003,
) to the valve holder.
1.2
Tighten the overpressure safety valve (003).
1.3
Attach the valve holder (002) to the test bench (008) or to the HP oil pump (006).
2
Do a check of the sealing pressure.
2.1
Operate the test bench (008) or the HP oil pump (006) to increase the pressure
to 1150 bar.
2.2
Keep the pressure constant for one minute.
2.3
Make sure that there are no leaks.
3
Do a check of the operation pressure.
3.1
Operate the test bench (008) or the HP oil pump (006) to increase the pressure
until the overpressure safety valve (003) opens.
3.2
Make sure that the overpressure safety valve (003) opens at between 1200 bar
and 1350 bar.
4
Complete the test.
4.1
Operate the test bench (008) or open the valve (005) on the HP oil pump (006)
to release the pressure.
4.2
Remove the overpressure safety valve (003) from the valve holder (002).
5
Record the results in the Inspection Report.
NOTE:
Unserviceable overpressure safety valves must be sent to the manufacturer, or
a WinGD authorized repair workshop for inspection and repair.
X82-B
AA00-5562-01AAA-360A-A
Maintenance Manual
Fuel rail - do a check of the overpressure safety valve
Winterthur Gas & Diesel Ltd.
- 585 -
Issue 001 2020-10
Summary of Contents for X82-B
Page 825: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 1 9...
Page 826: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 2 9...
Page 827: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 3 9...
Page 828: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 4 9...
Page 829: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 5 9...
Page 830: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 6 9...
Page 831: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 7 9...
Page 832: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 8 9...
Page 833: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 9 9...