![WinGD X82-B Maintenance Manual Download Page 567](http://html1.mh-extra.com/html/wingd/x82-b/x82-b_maintenance-manual_986581567.webp)
PROCEDURE
1
Turn the power supply of E85 “off”.
2
Remove the top cover from the actuator terminal box. Make sure that no particles or
liquids enter the box.
3
Put a bridging wire between terminals 6 and 35. See number 1 in
4
Put a bridging wire between terminals 5 and 43. See number 2 in
5
Turn the power supply of E85 “on”.
6
Push the switch. See number 3 in
NOTE:
If the switch is pushed correctly, the actuator moves to the maximum and
minimum position (self-adjustment).
NOTE:
The switch is very fragile. Make sure to use as little force as possible when
pushing it.
7
Wait until the movement of the fuel pump actuator stops.
8
Turn the power supply of E85 “off”.
9
Remove the two bridging wires. See numbers 1 and 2 in
10
Re-attach the top cover of the actuator terminal box.
11
Turn the power supply of E85 “on”.
Fig 10-14 Calibration illustration
X82-B
AA00-5583-00AAA-273A-A
Maintenance Manual
Fuel pump actuator - calibrate
Winterthur Gas & Diesel Ltd.
- 567 -
Issue 001 2020-10
Summary of Contents for X82-B
Page 825: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 1 9...
Page 826: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 2 9...
Page 827: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 3 9...
Page 828: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 4 9...
Page 829: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 5 9...
Page 830: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 6 9...
Page 831: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 7 9...
Page 832: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 8 9...
Page 833: ...Approved TIGHTENING INSTRUCTIONS Rev B Page 9 9...