Applications Guide
Network Busy Lamp Field (BLF)
A-16
Strata CIX Programming Vol.1 12/09
Programming Network BLF from Network eManager for Digital Telephones
Perform all of the following steps on the local CIX first, then repeat them on each of the remote CIXs.
1. Create the Node ID in
Note
If you have already created the Node ID using Strata Net, skip Step 1 and go to the next step.
2. Set up the IP address of the primary CIX using Program
“916 IP Configuration” on page 10-10
3. In Network eManager, select Strata Net > Node ID to set the Primary Node ID. Refer to
.
4. In Network eManager, select System > I/O Device. Refer to Program
.
•
00 Logical Device No. = 400 (BLF)
•
01 Device Connection = LAN
•
02 Device Port No. = 11
5. Define the LAN Device port number (11 in the example above). Select System > I/O Device, select the
LAN Device tab. Refer to
“801 Network Jack LAN Device Assignment”
following selections:
•
00 LAN Port No. = 11
•
01 Protocol = TCP
•
02 Application Type = Server
•
03 Data Flow = Asynchronization
•
04 Server Port No. = 6000
•
05 Client IP 1-4 No. = Default
•
06 Client Port No. = Default
•
07 Read Retry No. = 1
•
08 Write Retry No. = 1
•
09 CallerName Set to CSTA = No
6. Verify the DSS refresh time in System > System Timer, field 23 – Network DSS Refresh Timer. Refer to
7. From each remote CIX, repeat steps 1~6 to set up Network BLF.
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...