System
Dial Number Plan
4-8
Strata CIX Programming Vol.1 12/09
117 Public Dial Plan Digit Analysis
Prerequisite Program:
None
This program is used to prevent users from circumventing Destination Restriction (DR) by sending tones
directly to the PSTN before DR analysis is complete. It defines the number of digits expected in PSTN
numbers beginning with identified sequences.
For example, a number starting with the toll prefix “1” would be expected to be 11 digits long. Calls will be
cut through to the public network only after the expected number of digits have been received.
1. In Network eManager, click System > Public Numbering Plan.
2. Enter the Identifying Digits used for external calls.
3. Select Pattern Digit Length. Total digits beginning with the selected Prefix digit.
4.
Get
Default
sets all values to factory default.
5. Click
Submit
.
F
IELD
D
ESCRIPTION
00 Identifying Digits
Enter the initial identifying external digits. 1 to 7 digits may include wild
cards “X” and “N”.
Possible values:1~7 (N = 2~9 and X = 0~9) (default = no value)
01 Pattern Digit Length
Select the number of digits to follow the prefix number established
above. It is the total number of digits in a number beginning with the
00 Prefix Number entered above.
Possible values:0~64 (default = 0)
Default:
1NXX=11, N11=3, NXX=7
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...