Trunks
Strata CIX Programming Vol.1 12/09
6-17
T
runks
04 Pooled Key Group
If this line group is not assigned to ring a CO, GCO, or a Pooled line key, enter the
Destination type that should ring:
No Data - no destination will ring when the line rings into the system.
Dialing Digits - assigns the line to ring the directory number or access code defined
in the Destination Digits assignment.
DISA - assigns the line to ring in as a DISA call - DISA dial tone will be returned to
the caller.
Modem - assigns the line to ring the remote maintenance modem on the CIX
processor. Used to call into the system with an eManager PC and modem.
Night Bell - Assigns the line to cause the night relay to pulse
(one-sec.close/3-sec.open).
Possible values:1~6 CTX28, 1~32 CIX40, 1~32 CTX/CIX/100, 1~50 CTX/CIX 670
BCTU only or BBCU only, 1~128 CTX/CIX670 BCTU + BEXU or
BBCU + BECU, 1~50 CIX1200 HCTU only, 1~128 CIX1200 HCTU +
HEXAU, 1~220 CIX1200 HCTU + HEXBU
(default = 0)
05 Audio Day1 Dst
Type
06 Audio Day2 Dst
Type
07 Audio Night Dst
Type
If this line group is not assigned to ring a CO, GCO, or a Pooled line key, enter the
Destination type that should ring:
No Data - no destination will ring when the line rings into the system.
Dialing Digits - assigns the line to ring the directory number or access code defined
in the Destination Digits assignment.
DISA - assigns the line to ring in as a DISA call - DISA dial tone will be returned to
the caller.
Modem - assigns the line to ring the remote maintenance modem on the CIX
processor. Used to call into the system with an eManager PC and modem.
Night Bell - Assigns the line to cause the night relay to pulse (one-sec.close/3-
sec.open).
Possible values:No Data (default), Dialing Digits, DISA, Built-in Modem or Night Bell
Audio Day1 Dest
Audio Day2 Dest
Audio Night Dest
Enter the Destination Directory Number or Access Code.
Possible values:Up to 32 digits (default = no value)
If Dialing Digits is the Destination Type enter the Directory Number that the line
should ring. If the line should ring over external page, enter #31xx, where xx is the
external page group number. If the default page access code #31 was changed, use
the new page access code as the leading digits.
Line access codes and network routing numbers can also be entered to route
incoming calls back out to a public or private network number.
08 Data Day1 Dst Type
09 Data Day2 Dst Type
10 Data Night Dst Type
Select the Destination Type for data calls.
Possible values:No Data (default), Dialing Digits, DISA, Built-in Modem or Night Bell
F
IELD
D
ESCRIPTION
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...