This chapter provides Strata CIX system programming information for programmers using the Strata
Network eManager programming interface.
100 Cabinet Slot PCB Assignments
Prerequisite Program:
None
All PCBs, except the system processors, are assigned to cabinet slots using this command. The CIX has a
dedicated slot in the Base cabinet for the system processors so they do not require this assignment.
•
The CIX100 provides one Base (4) and one Expansion (Exp) cabinet (4) for a total of eight slots.
•
The CIX200 Base cabinet has three slots (S101~S103) and the Exp cabinet has four slots
(S201~S204) for a total of seven slots.
•
The CIX670 system provides one Base cabinet and up to six Exp cabinets. The Base cabinet has eight
slots and each of the six Exp cabinets have 10 slots for a total of 68 slots.
•
The CIX1200 system can be configured with up to 12 cabinets - one Base cabinet and up to 11
Expansion cabinets for a total of 118 slots.
1. In Network eManager, click System > Card Assignment. The Card Slot Assignment screen displays.
2. Cabinet (01~012) – Select the two-digit cabinet number to be assigned. The cabinet and slot number
appear in the cab/slot field.
-
Select 01 for CIX40.
-
Select 01 for Base and Exp. cabinet (CIX100).
-
Select 01 or 02 for CIX200.
-
Select 01 for Base and 02~07 respectively, for each Exp. cabinet (CIX670).
-
Select 01 for Base and 02~12 respectively, for each Exp. cabinet (CIX1200).
3. Slot (01~10) – Select the two-digit card slot number to be assigned.
-
Select 01~04 for Base slots and 05~08 for Exp. slots (CIX100).
-
Select 01~04 for CIX200 Base and Exp. slots. Slot 04 in the Base Cabinet is the LSLU card slot.
-
Select 01~08 for Base slots and 01~10 for Exp. slots (CIX670).
-
Select 01~08 for Base slots and 01~10 for Exp. slots (CIX1200).
Note
The CIX100 ACTU built-in relay is programmed as relay 5. For this relay operation, BIOU2 is
installed as default in a virtual equip position: Cabinet 2, Slot 5, PCB code 20 in Program 100. To
install an actual BIOU2 and disable the ACTU built-in relay, use the programming telephone to
remove the virtual BIOU2, then install the actual BIOU2 in Cabinet 01/Slot 01~08 in the normal
manner.
4. Select the PCB Type. Use the drop down menu to select the PCB type. The selected PCB type will
appear in the PCB Type field.
5. Click
Submit
to save your data.
Summary of Contents for CIX 200
Page 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Page 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Page 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Page 314: ...This page is intentionally left blank ...
Page 432: ...This page is intentionally left blank ...
Page 434: ...This page is intentionally left blank ...